mary sullivan posted a reply on Re: Subtherapeutic ACT values after standard he...
Thursday, Feb 12, 2026 at 11:18 AM
Said: I had to open a case for this same issue and I'm wondering if anyone has heard from Abbott after sending cartridges back for testing? The lot we are using is R25342. Our pharmacy has sent Heparin back to the vendors for testing as well....
Peggy Mann posted a reply on Re: Precision Dx multi panel urine drug testin...
Thursday, Feb 12, 2026 at 11:13 AM
Said: Good point, Kathleen. The cups we purchase also have adulterant detection.
Kathleen David posted a reply on Re: Precision Dx multi panel urine drug testin...
Thursday, Feb 12, 2026 at 10:57 AM
Said: It's Detectabuse Stat Skreen. Our cups also have adulterant detection, so that's an additional control set. I believe the clinics purchase from McKesson, but other distributors probably have it as well.
Peggy Mann posted a reply on Re: Precision Dx multi panel urine drug testin...
Thursday, Feb 12, 2026 at 10:55 AM
Said: Melva, according to the RN supervisor, she had to order directly from the company (that could be related to distributors she has to use related to purchasing at the university).The external QC product the clinic found which the ...
Jason Tang posted a new Topic
Thursday, Feb 12, 2026 at 10:08 AM
GEM5000 Cartridge Operation Question
Hi all, I have some questions towards GEM5000 cartridge operation:
1) For cases of specific sensor error appearing (after installation but before 30 days), is there a method to "cross out" the malfunction sensors and continue use this cartridge for the rest of menu?
2) Will it possible to disable quality check after the sample run to reduce the turnover time?
Any insight and comment will be appreciated.
Thanks
1) For cases of specific sensor error appearing (after installation but before 30 days), is there a method to "cross out" the malfunction sensors and continue use this cartridge for the rest of menu?
2) Will it possible to disable quality check after the sample run to reduce the turnover time?
Any insight and comment will be appreciated.
Thanks
MOST ACTIVE MEMBERS
James Beck
POCT Coordinator
UPMC
Peggy Mann
Ambulatory POCC & Program Manager
University of Texas Medical Branch
Kathleen David
Associate Director, Point of Care Testing
TriCore Reference Lab
Erika Deaton-Mohney BS, MT(ASCP), CPP
Technical Consultant
Sound Lab Consultant
Danyel Olson
POCC
Children's MN
Adonica Wilson
Enterprise Point of Care Supervisor
Nemours
SHARED LINKS
No Links added yet...
UPCOMING EVENTS
This area will display upcoming events as they approach on the calendar
Add New Module