Brittany Behrendt posted a reply on Re: iSTAT CG8 cartridges oderables
Monday, Nov 2, 2026 at 9:37 AM
Said: Our institute has everything separate for ordering since providers may not want the whole panel. All poc testing starts with the name POCT in front of the test to find the tests easier. So, we have POCT venous blood gas, POCT arterial b...
Angel Lorenzo posted a new Topic
Monday, Nov 2, 2026 at 8:28 AM
CMS/i-STAT Comparability Requirement Interpretation and Implementation
Hello POCC Colleagues,
I am interested in learning how other organizations are interpreting and operationalizing the recent CMS focus on instrument comparability requirements under 42 CFR §493.1281(a) as it relates to Point-of-Care Testing. According to recent communication from Abbott following discussions with CMS, the expectation appears to be that laboratories maintain a documented process demonstrating comparison of all patient-testing instruments at least twice p...
I am interested in learning how other organizations are interpreting and operationalizing the recent CMS focus on instrument comparability requirements under 42 CFR §493.1281(a) as it relates to Point-of-Care Testing. According to recent communication from Abbott following discussions with CMS, the expectation appears to be that laboratories maintain a documented process demonstrating comparison of all patient-testing instruments at least twice p...
Leslie Morman posted a reply on Re: Point of Care Education Needs
Monday, Nov 2, 2026 at 7:23 AM
Said: In addition to statistical data, I think covering steps involved in evaluating and selecting a new instrument or test kit would be helpful. Determining whether a test system meets the clinical and operational needs of the practice. ...
Kimberly Switzer posted a new Topic
Friday, Oct 30, 2026 at 5:40 PM
iSTAT CG8 cartridges oderables
Hi everyone,
For those of you using the Abbott i-STAT CG8+ cartridge, what test name/orderable are you using at your facility?
The CG8+ reports a broad menu of results, including blood gases, electrolytes, glucose, hematocrit, and calculated hemoglobin, so we're reviewing whether our current test name adequately reflects everything included in the panel.
Currently, one of our counterparts is using "Blood Gas Venous Panel," but that se...
Claire Morrison posted a reply on Re: Inconsistent results on DCA Vantage
Friday, Oct 30, 2026 at 3:46 PM
Said: When I called Siemens today I was told that there is an investigation into a small number of lots giving lower than expected results, but they could not say which lots as the investigation is ongoing.
MOST ACTIVE MEMBERS
James Beck
POCT Coordinator
UPMC
Peggy Mann
Ambulatory POCC & Program Manager
University of Texas Medical Branch
Kathleen David
Associate Director, Point of Care Testing
TriCore Reference Lab
Erika Deaton-Mohney BS, MT(ASCP), CPP
Technical Consultant
Sound Lab Consultant
Danyel Olson
POCC
Children's MN
Adonica Wilson
Enterprise Point of Care Supervisor
Nemours
SHARED LINKS
No Links added yet...
UPCOMING EVENTS
This area will display upcoming events as they approach on the calendar
Add New Module