For those that are using STATNotes and Meditech, do you know what the result codes are in the OBX 3 segment?  I am trying to get it started at our facility and I have it built and it is being received in Telcor, but I don't know what code Telcor needs to send it to Meditech.


 


Thanks!

2 Replies

Hi Jillian, it is the exact way the specific test is built in Meditech. For example, for arterial pH our Meditech result code that our IT LIS team built in the Meditech disctionary is ph-art


So, Telcor needs to know to use lowercase ph-art in OBX3. When you are building statnotes it is the same thing, each parameter is built in Meditech as a test in the dictionary, such as delsys for delivery system - so Telcor needs to know the exact result code built in the Meditech dictionary for each of your new Statnotes parameters.


Here is a sample MSH from our Meditech, I entered X's for the patient name and ID:


 



MSH|^~\&|34|MGA|||201804101737||ORU^R01|MSG201804104E4C7ED0|P|2.3|||AL|AL||
PID|1||||XXXXX^XXXXX^^||XXXXXXXXX|M||||||||||208755288
ORC|NW||
OBR|1|||AG|||201804101734|||111855||||201804101735|ARTERIAL||||||||||F|||||PORT
|||111855


OBX|1|ST|ph-art||7.351||||||F|||201804101734||111855


OBX|2|ST|pco2-art||42.4|mmHg|||||F|||201804101734||111855


OBX|3|ST|po2-art||58|mmHg|||||F|||201804101734||111855
OBX|4|ST|tco2-art||25|mmol/L|||||F|||201804101734||111855


OBX|5|ST|be-art||-2|mmol/L|||||F|||201804101734||111855


OBX|6|ST|hco3-art||23.7|mmol/L|||||F|||201804101734||111855


OBX|7|ST|o2sat-art||90|%|||||F|||201804101734||111855


OBX|8|ST|oper id-poc||111855||||||F|||201804101734||111855


OBX|9|ST|site-poc||380947||||||F|||201804101734||111855


OBX|10|ST|pt-temp||35.9||||||F|||201804101734||111855


OBX|11|ST|istat-com 1||NP||||||F|||201804101734||111855


OBX|12|ST|istat-com||NP||||||F|||201804101734||111855

Thanks!!!

Reply
Subgroup Membership is required to post Replies
Join POCT Listserv now
Jillian Cooper
over 8 years ago
2
Replies
0
Likes
0
Followers
988
Views
Liked By:
Suggested Posts
TopicRepliesLikesViewsParticipantsLast Reply
Labeling of POCT samples and devices
Felix Ortiz-Plaza
about 15 hours ago
10156
Kimberly Arnesen
about 14 hours ago
LeadCare II sample collection
Leslie Morman
about 17 hours ago
10128
Peggy Lindeman
about 16 hours ago
GH100 Training
Anita Belanger
about 17 hours ago
10151
Kenda Webb
about 17 hours ago