WELCOME TO THE POCT Listserv
This site is a public meeting place, hosted by CarePoint Solutions and moderated by Bill Donohue, that provides members of POCT Listserv with a shared calendar, discussion forums, file sharing and more. We encourage you to complete your profile and participate!
RECENT ACTIVITY
Adonica Wilson posted a new Topic
Tuesday, Jun 30, 2026 at 1:25 PM
TEG/ROTEM testing in pediatrics
Hi all,
Does anyone use the TEG or Rotem in a pediatric POCT arena? I am trying to figure out the high complexity operator part. Please feel free to contact me offline at awilson@nemours.org
Does anyone use the TEG or Rotem in a pediatric POCT arena? I am trying to figure out the high complexity operator part. Please feel free to contact me offline at awilson@nemours.org
Patti Hezel posted a new Topic
Tuesday, Jun 30, 2026 at 12:25 PM
Looking for better ways
Hello,
My Supervisor wanted me to reach out. Can you please see the questions below and respond if you can?
POC Device type:
# of devices of each type:
What areas or units are the devices used:
Do they have a usage protocol? If so, would they be willing to share your protocol?
How do they charge for the tests each device uses? Rolled into room charge? Billed individually?
Do you educate physicians on usage...
My Supervisor wanted me to reach out. Can you please see the questions below and respond if you can?
POC Device type:
# of devices of each type:
What areas or units are the devices used:
Do they have a usage protocol? If so, would they be willing to share your protocol?
How do they charge for the tests each device uses? Rolled into room charge? Billed individually?
Do you educate physicians on usage...
Miranda Cotter posted a reply on Re: epoc TCO2 linearity validation
Tuesday, Jun 30, 2026 at 12:09 PM
Said: We haven't started our validation yet, but we will be doing the Level 6. We are also going to potentially order Eurotrol Hypoxic and Hyperbaric to allow for a larger pO2 range.
Addison Barham posted a new Topic
Tuesday, Jun 30, 2026 at 11:19 AM
epoc TCO2 linearity validation
Hi All,
We are in the middle of our epoc validation and have come across a problem with TCO2 specifically. Our reportable range is 10-50 but the calibration material the vendor used while on site to validate only went from about 6.5-30. We know there is a GAS-ISE Metabolite Level 6 that would help us reach the high end of our range, but the vendor stated that customers typically do not need this for the validation. Can anyone elaborate on how they have gone about validating withou...
We are in the middle of our epoc validation and have come across a problem with TCO2 specifically. Our reportable range is 10-50 but the calibration material the vendor used while on site to validate only went from about 6.5-30. We know there is a GAS-ISE Metabolite Level 6 that would help us reach the high end of our range, but the vendor stated that customers typically do not need this for the validation. Can anyone elaborate on how they have gone about validating withou...
Autilia Sisti posted a reply on Re: Am I Overdoing It with my CAP Quality Cross...
Tuesday, Jun 30, 2026 at 10:36 AM
Said: We have 10 ABL90's set up as POC devices, and Respiratory has 11 devices in their department. We all use AQQ and SOQ as our instrument comparisons, so we too run them ourselves. In our scenario, it would be impossible for all QC l...
MOST ACTIVE MEMBERS
James Beck
POCT Coordinator
UPMC
Peggy Mann
Ambulatory POCC & Program Manager
University of Texas Medical Branch
Kathleen David
Associate Director, Point of Care Testing
TriCore Reference Lab
Erika Deaton-Mohney BS, MT(ASCP), CPP
Technical Consultant
Sound Lab Consultant
Danyel Olson
POCC
Children's MN
Adonica Wilson
Enterprise Point of Care Supervisor
Nemours
SHARED LINKS
No Links added yet...
UPCOMING EVENTS
This area will display upcoming events as they approach on the calendar
Add New Module