mary rickel posted a reply on Re: i-STAT hs-TnI Patient correlations
Tuesday, Jun 3, 2025 at 5:56 PM
Said: Hi, We just completed our hs-Trop validation on the i-Stat vs. Cobas T. Our Medical Director approved doing a concordance study between the two methods. Basically, comparing Abnormal hs-i to Abnormal hs-T and Normal to Normal likewise, ...
Kellie Graham posted a new Topic
Tuesday, Jun 3, 2025 at 5:51 PM
GEM 5000 CAP 6 Month Cal/Ver, Linearity, AMR, and Reference Range Verification
I am working on the CAP 6 month Cal/Ver, AMR, Reference Range and Linearity study on my GEM 5000’s. We usually use PVP to complete this in addition to patient samples to correlate to the lab. I have 3 devices in use where two are in OR and one in the Cath Lab. One of the Gem 5000’s in the OR is measuring lower than the TAE from the mean on tHb for PVP 1. When the last 6-month study was completed the instrument was in range of the tHb TAE. I have used 3 cartridge lots and run two differen...
Diane Cauteruccio posted a new Topic
Tuesday, Jun 3, 2025 at 5:16 PM
i-STAT hs-TnI Patient correlations
Hello POC community!
For those validating the new high sensitivity TnI test cartridge, what analyzer/s are you using for patient correlations?
We have a Roche Cobas 8000 in main lab, but that is a troponin T test, and the i-STAT cartridge is troponin I.
Abbott is telling us that cannot utilize this ("comparing apples to oranges") and do not need patients - use calibrations and QC to validate.
Thoughts? Comments? Suggestions?
Your assistance is appreciated!
Diane Cau...
For those validating the new high sensitivity TnI test cartridge, what analyzer/s are you using for patient correlations?
We have a Roche Cobas 8000 in main lab, but that is a troponin T test, and the i-STAT cartridge is troponin I.
Abbott is telling us that cannot utilize this ("comparing apples to oranges") and do not need patients - use calibrations and QC to validate.
Thoughts? Comments? Suggestions?
Your assistance is appreciated!
Diane Cau...
Karen Perry posted a reply on Re: Manual Sed Rates in Physician's Office
Tuesday, Jun 3, 2025 at 9:22 AM
Said: Do they hold a Certificate of Compliance or a Certificate of Waiver? If so, all they need to do is follow the manufacturer’s instructions.If they hold a Certificate of Accreditation, the rules are probably different. I would contact...
MELISSA INCORVIA posted a new Topic
Monday, Jun 2, 2025 at 1:08 PM
Manual Sed Rates in Physician's Office
Hello, I have an office that is doing manual Sediplast ESR Testing. How often would you run QC on this type of testing?
Thank you!
Thank you!
MOST ACTIVE MEMBERS
James Beck
POCT Coordinator
UPMC
Peggy Mann
Ambulatory POCC & Program Manager
University of Texas Medical Branch
Kathleen David
Associate Director, Point of Care Testing
TriCore Reference Lab
Erika Deaton-Mohney BS, MT(ASCP), CPP
Technical Consultant
Sound Lab Consultant
Danyel Olson
POCC
Children's MN
Adonica Wilson
Enterprise Point of Care Supervisor
Nemours
SHARED LINKS
No Links added yet...
UPCOMING EVENTS
This area will display upcoming events as they approach on the calendar
Add New Module